27.1 LPS diagnostic LED's

Status LED's on LPS unit
The LPS module contains in total 10 status LED's. 5 LED's per LPS unit. One orange, three green and one red LED. The orange
LED "LVPS OK" lights up immediately after the projector is switched on. All other status LED's of the LPS unit remains off. This is
the standby status of the LPS unit. Once the command is send to the LPS units to start up the projector lamp the green LED's are
lighting up one after the other. First the green LED "PFC OK", then the green LED "LPS OK" and finally, when the lamp is ignited,
the green LED "LAMP ON".
The red LED "ERR" remains off unless an error is detected inside the LPS unit or both LPS units where ordered to shutdown due to
a malfunction somewhere else inside the projector.
ERR PFC
LPS
OK
OK
Image 27-2
Diagnostic
Or.
Gr.
LVPS OK
PFC OK
OFF
OFF
ON
OFF
ON
ON
ON
ON
R59770072 FLM SERIES 19/03/2007
MAINS
INPUT
LAMP OUT
Gr.
Gr.
LPS OK
LAMP
OK
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
MAINS
INPUT
LAMP OUT
Re.
Diagnostic
ERR
OFF
No input voltage.
OFF
Standby modus of LPS unit.
OFF
PFC and LPS seems to work
normally but the lamp is not
ignited. This situation can be
the result of a bad lamp or
SPG module.
OFF
LPS unit is operating
normally. Projector lamp
is ignited.
27. Lamp power supply
LAMP ON / LVPS OK
Action
Switch on the projector.
Install another FLM
lamp house in case the
voltage on the "LAMP
OUT" pins is 140 volt
and you hear the SPG
module three times
clicking to ignite the
lamp.
Replace the SPG
module in case the
voltage value on the
"LAMP OUT" pins is 140
volt and you do not hear
the SPG module clicking
to ignite the lamp.
Replace the LPS
module in case the
voltage value on the
"LAMP OUT" pins is
below 140 volt and the
lamp is not ignited.