16.4 Pressure verification of the liquid cooling circuit

How to check the pressure of the liquid cooling circuit inside the projector ?
1. Remove the side cover of the projector, see "Removal of the side cover", page 73.
2. Check the pressure indicated on the internal manometer of the liquid cooling circuit.
Image 16-3
3. This pressure should be between 0,5 and 1 bar. If the pressure, indicated on the manometer, is out of range, inform the respon-
sible and qualified technicians, so they may take necessary corrective action.
4. Reinstall the side cover of the projector, see "Installation of the side cover", page 81.
R59770072 FLM SERIES 19/03/2007