1692 → 1699 : Formatter Related Errors - Barco FLM series Service Manual

Hide thumbs Also See for FLM series:
Table of Contents

Advertisement

3.2
1692 → 1699 : Formatter related errors
Error 1692 : "Form. PWRGood"
Situation
Formatter "Power Good" signal not
OK. The local power supplies on
the Formatter Interface Board fails.
The orange LED "PWRGood" (ref
A image 3-3 & image 3-4) on the
Formatter Interface Board remains
off.
The status LED's of the Formatter
Interface Board (FIB) are visible
through the filter grid behind the
front filter. So, you have to remove
the projector front cover and the
front filter first to see the LED's on
the FIB.
B
FLM
Image 3-3
Status LED's of the Formatter Interface Board (non HD version). Visible trough the grid behind the front filter.
A
Orange LED "PWRGood" OK.
B1 Green LED "+5V".
B2 Green LED "+3.3V".
B3 Green LED "+2.5V".
B4 Green LED "+2.1V".
C
Green LED "FPGA DONE".
R59770072 FLM SERIES 19/03/2007
Solution
Check if all wire units between the Formatter Interface Board and the three
formatter boards are not damaged. A damaged wire unit can cause a short circuit
in the local power supply of the Formatter Interface Board.
Check if none of the pins of the connectors on the FIB or formatter boards are
bend over.
Replace the Formatter Interface Board.
If the problem remains contact Barco for further instructions. The formatter boards
are malfunctioning and have to be replaced at the factory.
A
C
3. Troubleshooting
A
B1
B2
B3
B4
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flm r20+Flm hd18Flm hd14

Table of Contents