Omron e5ck User Manual page 175

Digital controller (programmable type)
Hide thumbs Also See for e5ck:
Table of Contents

Advertisement

APPENDIX
Mode
Parameter Name
Set point upper limit
Set point lower limit
PID / ON/OFF
Operation at power ON
End condition
Number of patterns
Program time unit
Step time/Rate of rise pro-
gramming
Time unit of ramp rate
Expan
Expan-
sion
i
PV start
Alarm during ramp step en-
able
Run all enable
α
AT calculated gain
Automatic return of display
mode
AT hysteresis
LB detection width
Event input assignment 1
Communication stop bit
Communication data length
Communication parity
Communication baud rate
Option
p
Communication unit No.
Transfer output type
Transfer output upper limit
Transfer output lower limit
*9 When temperature input is selected, the range of the sensor selected in the input type" parameter (setup mode) corresponds to the
scaling upper and lower limit value.
*10 Set the transfer output type parameter according to the following table.
Transfer Output Type
SP
:Present SP
PV
:Process value
O
:Manipulated variable (heat)
C-O
:Manipulated variable (cool)
D
Default : [SP]
A–8
Setting Range
Set point lower limit +1 to scaling upper limit
Scaling lower limit to Set point upper limit -1
PID / ON/OFF
CON/RST/RUN/MAN
RST/SP
1 to 4
HHMM/MMSS
TIME/PR
M/H
PV/SP
ON/OFF
ON/OFF
0.00 to 1.00
0.1 to 10.0
0 to 99
0.1 to 9.9
0.0 to 999.9
NON/RST/MAN/HOLD/ADV/PTN0 to 1
1/2
7/8
NONE/EVEN/ODD
1.2/2.4/4.8/9.6/19.2
0 to 99
SP/PV/O/C-O
*10
*10
Transfer Output Lower Limit to Transfer Output Upper Limit
-5.0 to 105.0% (standard control), 0.0 to 105.0% (heating and cooling control)
Unit
Default
Remarks
EU
1300
EU
-200
None
PID
None
CON
None
RST
None
1
None
HHMM
None
OFF
None
OFF
None
SP
None
ON
None
OFF
None
0.65
None
1.0
Sec
0
%FS
0.2
%FS
0.2
None
NON
bit
2
bit
7
None
EVEN
kbps
9.6
None
0
None
SP
*10
10
*10
*10
-1999 to 9999
-1999 to 9999
0.0 to 105.0%
Setting
*9
*9