Cooling
Cooling Type
System
Coolant
Coolant Capacity
Thermostat Type
Temperature(opened initially)
Temperature(perfectly opened)
Thermostat
Temperature(perfectly closed)
Stroke(perfectly opened)
Cooling Fan Type
Blade Number
Cooling Fan Diameter
Electric Cooling
Temperature At Low Speed ON
Fan
Temperature At Low Speed OFF
Temperature At High Speed ON
Temperature At High Speed OFF
Open Pressure of The Pressure Valve
Surge Tank
Surge Tank
Open Pressure of The Vacuum Valve
Water Pump Type
Impeller Diameter
Coolant Pump
Impeller Blade Number
Radiator Type
Core Width
Radiator
Core Height
Core Depth (Standard/Heavy Duty)
Resistance
(Coolant Temperature 50°C(122.4°F))
Coolant
Resistance
Temperature
(Coolant Temperature 85°C(185.4°F))
Sensor
Resistance
(Coolant Temperature 105°C(221.4°F))
Resistance
Engine Coolant
(Coolant Temperature 20°C(68.4°F))
Temperature
Resistance
Sensor
(Coolant Temperature 80°C(176.4°F))
DAEWOO M-150 BL2

SPECIFICATIONS

GENERAL SPECIFICATIONS

Description
ENGINE COOLING 1D – 17
Unit
Standard
Forced Water
Circulation
L/qt
3.8/4.00
Pellet Type
°C(°F)
82(180)
°C(°F)
95(203.4)
°C(°F)
80(176.4)
mm(in.)
8 (0.32)
Electric
EA
6
mm(inch)
300(11.8)
°C(°F)
93(199.8)
°C(°F)
90(194.4)
°C(°F)
100(212.4)
°C(°F)
97(207)
120–150
kPa (psi)
(17.4–21.8)
kPa (psi)
10 (1.5)
Centrifugal
mm(in.)
60(2.36)
EA
7
Cross–Flow
mm(in.)
458(18.03)
mm(in.)
295(11.61)
mm(in.)
16/27(0.63/1.06)
185.2
49.2
27.5
3,520
332