Step
Repair the electrical connections or the vacuum
lines as needed.
13
Is the repair complete?
Check the generator output voltage.
14
Is the generator voltage within the value specified?
Repair the generator.
15
Is the repair complete?
1. Check for intermittent Electric Exhaust Gas
Recirculation (EEGR) valve operation.
16
2. Repair or replace any components as needed.
Is the repair complete?
Repair the fuel system as needed.
17
Is the repair complete?
Replace the fuel filter.
18
Is the repair complete?
Replace the leaking or restricted fuel injectors.
19
Is the repair complete?
DAEWOO M-150 BL2
Surges or Chuggles (Cont'd)
Action
ENGINE CONTROLS 1F – 287
Value(s)
Yes
System OK
12–16 V
Go to Step 16
System OK
System OK
System OK
System OK
System OK
No
Go to Step 15