Powering On the SRX550 High Memory Services Gateway

Related
Documentation

Powering Off the SRX550 High Memory Services Gateway

120
To power on the services gateway:
Ensure that you have connected the power supply to the device.
1.
Insert the plug of the power supply adapter into an AC or DC power source receptacle.
2.
a. Using AC Power supply—Insert the appliance coupler end of the power cord into
the appliance inlet on the power supply and the power cord plug into an external
AC power source receptacle.
b. Using DC power supply—Connect DC power cables to the
the other ends to an external DC power source. If you have two DC power sources
and wish to deploy A/B feed redundancy for the services gateway, also connect
DC power cables to the
power source.
CAUTION:
proper polarity. The power source cables might be labeled (+) and (–)
to indicate their polarity. There is no standard color coding for DC power
cables. The color coding used by the external DC power source at your
site determines the color coding for the leads on the power cables that
attach to the terminals on the power supply.
Turn on the power to the AC or DC power receptacle.
3.
The device starts automatically as the power supply completes its startup sequence.
The POWER LED (on the front panel of the chassis) lights during startup and remains
on steadily when the services gateway is operating normally.
Connecting the SRX550 High Memory Services Gateway to the AC Power Source on
page 115
Connecting the SRX550 High Memory Services Gateway to a DC Power Source on
page 117
Grounding the SRX550 High Memory Services Gateway on page 106
Resetting the SRX550 High Memory Services Gateway on page 154
Powering Off the SRX550 High Memory Services Gateway on page 120
SRX550 High Memory Services Gateway Front Panel on page 14
To power off the services gateway, press the Power button on the front of the services
gateway and hold it for 10 seconds. The services gateway immediately shuts down.
B+
and
B-
terminals and the other ends to an external DC
You must ensure that power connections maintain the
and
terminals and
A+
A-