You can front-mount the SRX550 High Memory Services Gateway in a rack. Many types
of racks are acceptable, including four-post (telco) racks, enclosed cabinets, and
open-frame racks.
NOTE:
If you are installing multiple devices in one rack, install the lowest one
first and proceed upward in the rack.
To install the services gateway in a rack:
Position a mounting bracket on each side of the chassis.
1.
Use a Phillips (+) screwdriver, number 2 to install the screws that secure the mounting
2.
brackets to the chassis. Use either the front mount position, as shown in
Figure 17 on page
97, or the center mount position as shown in

Figure 17: Installing the Rack Mount Brackets (Front Mount Position)

Figure 18 on page
98.