Table 7: Srx550 High Memory Services Gateway Front Panel Leds - Juniper SRX550 Hardware Manual

Highmemoryservicesgateway
Hide thumbs Also See for SRX550:
Table of Contents

Advertisement

SRX550 High Memory Services Gateway Hardware Guide

Table 7: SRX550 High Memory Services Gateway Front Panel LEDs

LED Label
LED State
ALARM
On Steadily
Off
STATUS
On Steadily
Off
POWER
Steadily on
Off
HA
Steadily on
Off
MPIM-1,
On Steadily
MPIM-2
Off
18
LED Color
Description
Amber
Indicates a major alarm, such as low Services Processing Unit (SPU) memory
(less than 10% remaining), session full, maximum number of VPN tunnels reached,
high availability (HA) status changed, or redundant group member not found.
Red
Indicates a critical alarm, such as a failure of a hardware component or software
module.
Unlit
Indicates that the device is starting up.
NOTE:
When the system is up and running, if the ALARM LED is off, it indicates
that no alarms are active on the device.
Green
The services gateway is functioning normally.
Amber
The services gateway is starting up, running diagnostics, or shutting down.
Red
The services gateway has failed.
Unlit
The services gateway is powered off.
Green
The services gateway is functioning normally and that the services gateway and
all power supply units (PSUs) are receiving power.
Red
At least one PSU has failed.
Amber
The Power button has been pressed and the services gateway is shutting down.
Unlit
The services gateway is not receiving power.
Green
All configured high availability links are available.
Red
High availability links are not working as expected and a cluster member might
be missing or unreachable.
Amber
Some configured high availability links are down, but enough links are still active
for full high availability functionality. In this situation, performance might be
reduced, current bandwidth could cause packet drops, or a single point of failure
might now exist.
Unlit
High availability is not enabled.
Green
The Mini-PIM in the corresponding slot is functioning normally.
Red
The Mini-PIM hardware in the corresponding slot has failed or its anti-counterfeit
check failed.
Unlit
There is no Mini-PIM in the corresponding slot, or that the Mini-PIM is not detected
by the device.