Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
Error code
BA154070
BA170000
BA170100
BA170201
BA170202
BA170203
BA170210
72
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description
The receive operation failed.
NVRAMRC initialization failed; device
test failed
NVRAM data validation check failed
The firmware was unable to expand
target partition - saving configuration
variable
The firmware was unable to expand
target partition - writing event log entry
The firmware was unable to expand
target partition - writing VPD data
Setenv/$Setenv parameter error - name
contains a null character
Action
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Shut down the blade server; then, restart it.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.