Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
651-841
152 2E2
651-842
2E1
651-90x
652-600
652-610
210
652-611
210
652-612
D01
652-613
D01
652-623
2C6
652-630
307
652-631
307
652-632
307
652-633
307
652-634
307
652-664
302
652-665
303
652-666
304
652-669
2CD
652-66A
2CE
652-66B
2CC
136
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description and Action
Sensor detected a voltage outside of the normal range. Go to "Performing the
checkout procedure" on page 184.
Sensor detected an abnormally high internal temperature. Make sure that:
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. All system covers are closed.
4. There are no fan failures.
Platform-specific error. Call your support center.
A non-critical error has been detected: uncorrectable memory or unsupported
memory. Schedule deferred maintenance. Examine the memory modules and
determine if they are supported types. If the modules are supported, then replace
the appropriate memory modules.
A non-critical error has been detected: CPU internal error. Schedule deferred
maintenance. Go to "Performing the checkout procedure" on page 184.
A non-critical error has been detected: CPU internal cache or cache controller error.
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
184.
A non-critical error has been detected: external cache parity or multi-bit ECC error.
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
184.
A non-critical error has been detected: external cache ECC single-bit error. Schedule
deferred maintenance. Go to "Performing the checkout procedure" on page 184.
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to "Performing the checkout procedure" on page 184.
A non-critical error has been detected: I/O expansion bus parity error. Schedule
deferred maintenance. Go to "Performing the checkout procedure" on page 184.
A non-critical error has been detected: I/O expansion bus time-out error. Schedule
deferred maintenance. Go to "Performing the checkout procedure" on page 184.
A non-critical error has been detected: I/O expansion bus connection failure.
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
184.
A non-critical error has been detected: I/O expansion unit not in an operating state.
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
184.
A non-critical error has been detected: internal device error. Schedule deferred
maintenance. Go to "Performing the checkout procedure" on page 184.
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to "Performing the checkout procedure" on page 184.
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to "Performing the checkout procedure" on page 184.
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to "Performing the checkout procedure" on page 184.
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred G maintenance. Go to "Performing the checkout procedure" on page 184.
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to "Performing the checkout procedure" on page 184.
A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to "Performing the checkout procedure" on page 184.