Table 14. B200xxxx Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Reference Code
Description
B2008151
System firmware detected an error.
B2008152
No active system processors.
B2008160
A problem occurred during the
migration of a partition.
B2008161
A problem occurred during the
migration of a partition.
B200A100
A partition ended abnormally; the
partition could not stay running and
shut itself down.
B200A101
A partition ended abnormally; the
partition could not stay running and
shut itself down.
B200A140
A lower priority partition lost a
usable processor to supply it to a
higher priority partition with a bad
processor.
B200B07B
Informational system log entry only.
B200B215
A problem occurred after a partition
ended abnormally.
There was a communications
problem between this partition's
service processor and the platform's
service processor.
B2005127
Timeout occurred during a main
store dump IPL.
B2D03001
Informational system log entry only.
B2D03002
Informational system log entry only.
B200C1F0
An internal system firmware error
occurred during a partition
shutdown or a restart.
B200D150
A partition ended abnormally; there
was a communications problem
between this partition and the code
that handles resource allocation.
B200E0AA
A problem occurred during the
power off of a partition.
38
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Action
Use the Integrated Virtualization Manager (IVM) or
management console to increase the Logical Memory
Block (LMB) size, and to reduce the number of virtual
devices for the partition.
Verify that processor resources are assigned to the
partition.
Contact IBM support.
Contact IBM support.
1. Check the error logs and take the actions for the error
codes that are found.
2. Go to "Isolating firmware problems" on page 218.
1. Check the error logs and take the actions for the error
codes that are found.
2. Go to "Isolating firmware problems" on page 218.
Evaluate the entire LPAR configuration. Adjust partition
profiles with the new number of processors available in
the system.
No corrective action is required.
Restart the platform.
There was not enough memory available for the dump to
complete before the timeout occurred. Retry the main
store dump IPL, or else power on the partition normally.
No corrective action is required.
No corrective action is required.
Go to "Isolating firmware problems" on page 218.
Check for server firmware updates; then, install the
updates if available.
Go to "Isolating firmware problems" on page 218.