Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
815-100
815
815-101
815
815-102
815
815-200
815 7C0
815-201
815
817-123
817
817-124
817
817-210
817
817-211
817
817-212
151
817-213
817
817-215
817
817-217
817
887-101
887
887-102
887-103
887
887-104
887
887-105
887
887-106
887
887-107
887
887-108
887
887-109
887
887-110
887
887-111
887
887-112
887
138
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description and Action
The floating-point processor test failed. Go to "Performing the checkout procedure"
on page 184.
Floating point processor failed. Go to "Performing the checkout procedure" on page
184.
Floating point processor failed. Go to "Performing the checkout procedure" on page
184.
Power-on self-test indicates a processor failure. Go to "Performing the checkout
procedure" on page 184.
Processor has a status of failed. Processors with a failed status are deconfigured and
therefore cannot be tested or used by the system. Go to "Performing the checkout
procedure" on page 184.
The I/O planar time-of-day clock test failed. Go to "Performing the checkout
procedure" on page 184.
Time of day RAM test failed. Go to "Performing the checkout procedure" on page
184.
The time-of-day clock is at POR. Go to "Performing the checkout procedure" on
page 184.
Time of day POR test failed. Go to "Performing the checkout procedure" on page
184.
The battery is low. Go to "Performing the checkout procedure" on page 184.
The real-time clock is not running. Go to "Performing the checkout procedure" on
page 184.
Time of day clock not running test failed. Go to "Performing the checkout
procedure" on page 184.
Time of day clock not running. Go to "Performing the checkout procedure" on page
184.
POS register test failed. Go to "Performing the checkout procedure" on page 184.
887I/O register test failed. Go to "Performing the checkout procedure" on page 184.
Local RAM test failed. Go to "Performing the checkout procedure" on page 184.
Vital Product Data (VPD) failed. Go to "Performing the checkout procedure" on page
184.
LAN coprocessor internal tests failed. Go to "Performing the checkout procedure" on
page 184.
Internal loopback test failed. Go to "Performing the checkout procedure" on page
184.
External loopback test failed. Go to "Performing the checkout procedure" on page
184.
External loopback test failed. Go to "Performing the checkout procedure" on page
184.
External loopback parity tests failed. Go to "Performing the checkout procedure" on
page 184.
External loopback fairness test failed. Go to "Performing the checkout procedure" on
page 184.
External loopback fairness and parity tests failed. Go to "Performing the checkout
procedure" on page 184.
External loopback (twisted pair) test failed. Go to "Performing the checkout
procedure" on page 184.

Hide quick links: