IBM power PS700 Problem Determination And Service Manual page 191

Hide thumbs Also See for power PS700:
Table of Contents

Advertisement

Table 28. ssss-102 through ssss-640 SRNs (continued)
SRN
FFC
ssss-122
ssss
ssss-124
ssss
ssss-126
ssss 252B
ssss-128
252B ssss
software
ssss-129
252B ssss
software
ssss-130
ssss
ssss-132
ssss
Description and action
A SCSD reservation conflict error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
A SCSD check condition error occurred.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
A software error was caused by a hardware failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
The error log analysis indicates a hardware failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
Error log analysis indicates a SCSD bus problem.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
Error log analysis indicates a problem reported by the disk drive's self-monitoring
function.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
A disk drive hardware error occurred.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
179