Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
A03-16x
I/O Expansion unit not in an operating
state.
A05-00x
Error log analysis indicates an
environmental and power warning, but
the failure could not be isolated.
A05-01x
Sensor indicates a fan has failed.
A05-02x
System shutdown due to a fan failure.
A05-03x
Sensor indicates a voltage outside
normal range.
A05-04x
System shutdown due to voltage
outside normal range.
A05-05x
Sensor indicates an abnormally high
internal temperature.
FRU/action
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Make sure that:
a. The room ambient temperature is within
the system operating environment.
b. There is unrestricted air flow around the
system.
c. All system covers are closed.
d. There are no fan failures
2. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
3. If no entry is found, Replace the
system-board.
Chapter 2. Diagnostics