Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN
A1D-34x
A1D-35x
A1D-37x
A1D-38x
A1D-40x
A1D-50x
A24-000
176
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description
A non-critical error has been detected:
Wire Test Error.
A non-critical error has been detected:
Mainstore or Cache IPL Diagnostic
Error.
A non-critical error has been detected:
Clock or PLL Error.
A non-critical error has been detected:
Hardware Scan or Initialization Error.
A non-critical error has been detected:
Presence/Detect Error (Mis-Plugged).
Recoverable errors on resource indicate
a trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The
system is operating with the potential
for an unrecoverable error.
Spurious interrupts on shared interrupt
level have exceeded threshold
FRU/action
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. If repair is not immediately available, reboot
and the resource will be deconfigured;
operations can continue in a degraded mode.
2. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
3. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log. If an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. Replace part numbers reported by the
diagnostic program.
3. If no entry is found, Replace the
system-board.