IBM power PS700 Problem Determination And Service Manual page 67

Hide thumbs Also See for power PS700:
Table of Contents

Advertisement

Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
Error code
BA010013
BA010014
BA010015
BA010020
BA012010
BA012011
BA012012
BA012013
Description
The information in the error log entry
for this SRC provides network trace
data.
The information in the error log entry
for this SRC provides network trace
data.
The information in the error log entry
for this SRC provides network trace
data.
A trace entry addition failed because of
a bad trace type.
Opening the TCP node failed.
TCP failed to read from the network
TCP failed to write to the network.
Closing TCP failed.
Action
Informational message. No action is required.
Informational message. No action is required.
Informational message. No action is required.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
Chapter 2. Diagnostics
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents