IBM power PS700 Problem Determination And Service Manual page 175

Hide thumbs Also See for power PS700:
Table of Contents

Advertisement

Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
A05-21x
System shutdown due to Over
temperature condition.
A05-22x
System shutdown due to over
temperature and fan failure.
A05-24x
Power Fault specifically due to internal
battery failure.
A0D-00x
Error log analysis indicates an error
detected by the Service Processor, but
the failure could not be isolated.
A0D-06x
Service Processor reports unknown
communication error.
A0D-07x
Internal service processor firmware
error or incorrect version.
A0D-08x
Other internal Service Processor
hardware error.
FRU/action
1. Make sure that:
a. The room ambient temperature is within
the system operating environment.
b. There is unrestricted air flow around the
system.
c. All system covers are closed.
d. There are no fan failures
2. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
3. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
Chapter 2. Diagnostics
163