Table 15. B700xxxx Licensed internal code SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
F106
F107
F108
F10A
F10B
F10C
F120
F130

BA000010 to BA400002 Partition firmware SRCs

The power-on self-test (POST) might display an error code that the partition firmware detects.
Table 16 describes error codes that might be displayed if POST detects a problem. The description also
includes suggested actions to correct the problem.
Note: For problems persisting after completing the suggested actions, see "Checkout procedure" on page
184 and "Solving undetermined problems" on page 227.
Table 16. BA000010 to BA400002 Partition firmware SRCs
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
Error code
BA000010
48
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description
System firmware detected an error
System firmware detected an error.
A firmware error caused the system to
terminate.
System firmware detected an error
A processor resource has been disabled
due to hardware problems
The platform LIC detected an internal
problem performing Partition Mobility.
Informational system log entry only.
Thermal Power Management Device
firmware error was detected.
Description
The device data structure is corrupted
Action
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
260.
1. Collect the event log information.
2. Go to "Isolating firmware problems" on
page 218.
1. Collect the event log information.
2. Go to "Isolating firmware problems" on
page 218.
Look for and correct B1xxxxxx errors.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
260.
1. Collect the event log information.
2. Go to "Isolating firmware problems" on
page 218.
No corrective action is required.
Check for server firmware updates; then,
install the updates if available.
Action
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.