B200Xxxx Logical Partition Srcs - IBM power PS700 Problem Determination And Service Manual

Hide thumbs Also See for power PS700:
Table of Contents

Advertisement

B200xxxx Logical partition SRCs

A B200xxxx SRC is a logical partition reference code that is related to logical partitioning.
Table 14 describes system reference codes that might be displayed if system firmware detects a problem.
Suggested actions to correct the problem are also listed.
Note: For problems persisting after completing the suggested actions, see "Checkout procedure" on page
184 and "Solving undetermined problems" on page 227.
Table 14. B200xxxx Logical partition SRCs
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Reference Code
Description
B2001130
A problem occurred during the
migration of a partition
You attempted to migrate a partition
to a system that has a power or
thermal problem. The migration will
not continue.
B2001131
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
B2001132
A problem occurred during the
startup of a partition.
A platform firmware error occurred
while it was trying to allocate
memory. The startup will not
continue.
B2001133
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
B2001134
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
B2001140
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
B2001141
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Action
Look for and fix power or thermal problems and then
retry the migration.
Check for server firmware updates; then, install the
updates if available.
Collect a platform dump and then go to "Isolating
firmware problems" on page 218.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
29