Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
252B-719
252B
252B-720
252B
252B-721
252B
252B-722
252B
252B-723
252B
254E-201
254E 221
254E-601
254
254E-602
254
254E-603
254
254E-604
254
254E-605
254
254E-606
254
254E-701
254E 221
254E-702
254E 221
2567-xxx
2567
144
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description and Action
Device bus termination power lost or not detected.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
Adapter detected device bus failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
Temporary adapter detected device bus failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
Device bus interface problem.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
Device bus interface problem.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
Adapter configuration error. Go to "Performing the checkout procedure" on page
184.
Error log analysis indicates adapter failure. Go to "Performing the checkout
procedure" on page 184.
Error log analysis indicates an error attention condition. Go to "Performing the
checkout procedure" on page 184.
Error log analysis indicates that the microcode could not be loaded on the adapter.
Go to "Performing the checkout procedure" on page 184.
Error log analysis indicates a permanent adapter failure. Go to "Performing the
checkout procedure" on page 184.
Error log analysis indicates permanent adapter failure is reported on the other port
of this adapter. Go to "Performing the checkout procedure" on page 184.
Error log analysis indicates adapter failure. Go to "Performing the checkout
procedure" on page 184.
Error log analysis indicates permanent adapter failure. Go to "Performing the
checkout procedure" on page 184.
Error log analysis indicates permanent adapter failure is reported on the other port
of this adapter. Go to "Performing the checkout procedure" on page 184.
USB integrated system-board and chassis assembly. Go to "Performing the checkout
procedure" on page 184.