Table 15. B700xxxx Licensed internal code SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
6971
6972
6973
6974
6978
6979
697C
6980
6981
6984
6985
6987
46
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description
PCI bus failure
System bus error
System bus error
Informational system log entry only.
Informational system log entry only.
Informational system log entry only.
Connection from service processor to
system processor failed.
RIO, HSL or 12X controller failure
System bus error.
Informational system log entry only.
Remote I/O (RIO), high-speed link
(HSL), or 12X loop status message.
Remote I/O (RIO), high-speed link
(HSL), or 12X connection failure.
Action
1. Use the "PCI expansion card (PIOCARD)
problem isolation procedure" on page 194
to determine the failing component.
2. If the problem persists, replace the
system-board and chassis assembly, as
described in "Replacing the FRU
system-board and chassis assembly" on
page 260.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
260.
1. Use the "PCI expansion card (PIOCARD)
problem isolation procedure" on page 194
to determine the failing component.
2. If the problem persists, replace the
system-board and chassis assembly, as
described in "Replacing the FRU
system-board and chassis assembly" on
page 260.
No corrective action is required.
No corrective action is required.
No corrective action is required.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
260.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
260.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
260.
No corrective action is required.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
260.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
260.

Hide quick links: