IBM power PS700 Problem Determination And Service Manual page 215

Hide thumbs Also See for power PS700:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Isolation
Symptom
Procedure Code
FSPSP02
This procedure is for
boot failures that
terminate very early
in the boot process or
when the
management card or
the VPD data on the
management card is
not operational or is
not present.
FSPSP03
A system operator or
user error has
occurred.
A problem has been
FSPSP04
detected in the
service processor
firmware.
FSPSP05
The service processor
has detected a
problem in the
platform firmware.
Action
If the SRC is B1xxB107 or B1xxB108
The system has detected a problem with a clock card.
1. Replace the system board and chassis assembly, as described in
"Replacing the FRU system-board and chassis assembly" on page
260.
If the SRC is B1xxB106
The system has detected that the planars are deconfigured.
1. Replace the system board and chassis assembly, as described in
"Replacing the FRU system-board and chassis assembly" on page
260.
If the SRC is B1xxB110 or B1xxB111
The system has detected that all of the I/O bridges are deconfigured.
1. Replace the system board and chassis assembly, as described in
"Replacing the FRU system-board and chassis assembly" on page
260.
1. Replace the management card, as described in "Removing the tier 2
management card" on page 255 and "Installing the tier 2
management card" on page 256.
2. After replacing the card and installing the blade server in the chassis
unit and before rebooting the blade server or performing other
operations, ensure that the initialization of the management card
VPD occurs by waiting for the management module to discover the
blade server. Otherwise, the system might fail to IPL.
3. If the problem persists, replace the system board and chassis
assembly, as described in "Replacing the FRU system-board and
chassis assembly" on page 260.
Refer to the documentation for the function you were attempting to
perform.
1. Verify that the operating system is running. If it is running, perform
an in-band firmware update, as described in "Updating the
firmware" on page 263.
2. If the problem persists, replace the system board and chassis
assembly, as described in "Replacing the FRU system-board and
chassis assembly" on page 260.
1. Verify that the operating system is running. If it is running, perform
an in-band firmware update, as described in "Updating the
firmware" on page 263.
2. If the problem persists, replace the system board and chassis
assembly, as described in "Replacing the FRU system-board and
chassis assembly" on page 260.
203
Chapter 2. Diagnostics