Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
Error code
BA09000D
BA09000E
BA09000F
BA090010
BA090011
Description
The media is unsupported or not
recognized.
The media is not formatted correctly.
Media is not present
The request sense command failed.
The retry limit has been exceeded.
Action
1. Insert new media of the correct type.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Insert the media.
2. Insert new media of the correct type.
3. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Insert new media with the correct format.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Troubleshoot the SCSD devices.
2. Verify that the SCSD cables and devices are
properly plugged. Correct any problems
that are found.
3. Replace the SCSD cables and devices.
4. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Troubleshoot the SCSD devices.
2. Verify that the SCSD cables and devices are
properly plugged. Correct any problems
that are found.
3. Replace the SCSD cables and devices.
4. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
Chapter 2. Diagnostics
65