Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
2640-134
2640
2640-136
2640 2631
2D02-xxx
2631
2E00-201
2E00 221
2E00-601
2E00
2E00-701
2E00 221
2E10-201
2E10 221
2E10-601
2E10
2E10-602
2E10
2E10-603
2E10
2E10-604
2E10
Description and Action
Hardware command or DMA failure. Go to "Performing the checkout procedure" on
page 184.
Timeout waiting for controller or drive with no busy status. Go to "Performing the
checkout procedure" on page 184.
Generic reference for USB controller/adapter - system-board and chassis assembly.
Go to "Performing the checkout procedure" on page 184.
Configuration error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
EEPROM read error
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
Permanent adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
Adapter configuration error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
Error Log Analysis indicates adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
Error Log Analysis indicates an Error Attention condition.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
Error Log Analysis indicates that the microcode could not be loaded on the adapter.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
Error Log Analysis indicates a permanent adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
149