IBM power PS700 Problem Determination And Service Manual page 270

Hide thumbs Also See for power PS700:
Table of Contents

Advertisement

Before you complete this procedure, install the management card, as described in Installing the
management card.
PowerVM is one of the Capacity on Demand advanced functions. Capacity on Demand advanced
functions are also referred to as Virtualization Engine systems technologies or Virtualization Engine
technologies (VET).
To locate your VET code and then install the code on your blade server, complete the following steps:
1. Power on the blade server. If a Virtual I/O Server (VIOS) partition is installed, power on only the
VIOS partition. If VIOS is not installed, power on one of the partitions.
2. List the activation information that you must supply when the new VET activation code is ordered
through one of the following methods:
v By using Hardware Management Console (HMC):
a. In the navigation area, expand Systems Management.
b. Select Servers.
c. In the contents area, select the destination blade server.
d. Click Tasks > Capacity on Demand (CoD) > PowerVM > View Code Information.
The following is an example of the PowerVM output:
Note: When you request the activation code, you must supply the information that is
emphasized in the following example.
CoD VET Information
System type: 7895
System serial number: 12-34567
Anchor card CCIN: 52EF
Anchor card serial number: 01-231S000
Anchor card unique identifier: 30250812077C3228
Resource ID: CA1F
Activated Resources: 0000
Sequence number: 0040
Entry check: EC
Go to step 3.
v By using Integrated Virtualization Manager (IVM):
a. Start the IVM, if it is not running already.
b. In an IVM session, enter the lsvet -t code command.
The following is an example of the lsvet command output:
Note: When you request the activation code, you must supply the information that is
emphasized in the following example.
sys_type=7895,sys_serial_num=12-34567,anchor_card_ccin=52EF,
anchor_card_serial_num=01-231S000, anchor_card_unique_id=30250812077C3228,
resource_id=CA1F,activated_resources=0000,sequence_num=0040, entry_check=EC
Go to step 3.
v By using IBM Systems Director Management Console (SDMC):
a. On the Welcome page, click Resources.
b. Expand Hosts, and select the destination host.
c. Click Actions, and select System Configuration > Capacity on Demand (CoD).
d. In the Capacity on Demand window, select Advanced Functions from the Select On Demand
Type list, and then select PowerVM.
e. Click View Code Information.
The following is an example of the PowerVM output:
258
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents