Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN
A01-06x
A01-07x
A01-08x
A02-00x
A02-01x
A02-03x
A02-04x
A02-05x
158
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description
Time-out error waiting for I/O.
System bus parity error.
System bus protocol/transfer error.
Error log analysis indicates an error
detected by the memory controller, but
the failure could not be isolated.
Uncorrectable Memory Error.
Correctable error threshold exceeded.
Memory Control subsystem internal
error.
Memory Address Error (invalid address
or access attempt).
FRU/action
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.