Did Digit Length Selection - NEC Xen IPK Programming Manual

Hide thumbs Also See for Xen IPK:
Table of Contents

Advertisement

December 2004

DID Digit Length Selection

General Description
This Memory Block defines the Direct Inward Dialling (DID) digit length in Memory
Block 1-1-22.
Display
Data
No.
2 0 : D I D
T I M E
Programming Procedures
Go off-line.
1
Press LK1 + LK1 +
2
BK
3
Enter the data using the dial pad.
Note:
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
I
~
to enter numeric data 2, 3, or 4
Q
to insert a pause
U
to clear all data
N
4
Press
to write the data.
P
Press
to go back on-line.
5
Related Programming
M.B. Number
1-1-21
DID Digit Conversion Assignment
1-1-22
DID Digit Conversion Table & DNIS Assignment
1-1-23
DID Forward Station Number for Busy Station or Undefined Digit
5-00
Digit Add/Del for Tie Line Networking
DRAFT 3
54 – Chapter 1
Setting
Title
Data
D G T
2
D I S P L A Y
to access the Memory Block.
Memory Block Name
NEC Business Solutions Ltd
1-1-20
System Mode
1
Submode
1
Data No.
20
PC Programming
+ ALN
Default Values
2
DID Digit Length Selection, 1-1-20

Advertisement