Did Basic Data Setup - NEC SL2100 Programming Manual

Hide thumbs Also See for SL2100:
Table of Contents

Advertisement

SL2100
Level:
IN
Description
Use Program 22-09 : DID Basic Data Setup to define the basic setting of Dial-In incoming calls for
Program
each trunk group.
22
Input Data
Item
No.
01
Dial-In Receive digit
02
Received Vacant
Number Operation
03
Sub-Addressing
Mode
04
DID Receiving Mode
for ISDN
05
Local Code Digits
06
Local Code
07
Pilot Code
08
T302 Time-out Opera-
tion
Conditions
None
2-294
Program 22 : Incoming Call Setup
Trunk Group Number
Item
Input Data
1 ~ 8
0 = Disconnect (call de-
nied)
1 = Transfer (call routed
to PRG 22-12)
0 = Extension # Specify
(Intercom)
1 = DID Conversion Ta-
ble
0 = Enbloc Receiving
1 = Overlap Receiving
0 ~ 15 (0 = No Local
Code)
Dial (maximum 16 digits) (Only Overlap Receiving Mode)
Dial (1 digit : 0 ~ 9)
0 = Disconnect (Cut)
1 = Transfer (Refer to
Program 22-12 : DID In-
tercept Ring Group.)

22-09 : DID Basic Data Setup

1 ~ 50
Description
Enter the number of digits the table ex-
pects to receive from the Telco. Use this
program to make the system compatible
with 3- and 4-digit DID service. If ISDN
trunks, we analyze the last digits that are
set here. If it is T-1 or analog DID, it ana-
lyzes the first digits that are assigned here.
If the system receives a DID that is not
routed this program sets what the system
does with the call.
If the setting data is a (0), Disconnect, the
system will deny the call.
If the setting data is a (1), Transfer, the call
will be routed to the ring group specified in
PRG 22-12-01.
(Only Overlap Receiving Mode)
(Only Overlap Receiving Mode)
(Only Overlap Receiving Mode)
Program 22 : Incoming Call Setup
ISSUE 2.0
Default
4
0
0
0
0
No Setting
No Setting
0

Hide quick links:

Advertisement

Table of Contents
loading