Alcatel-Lucent 7705 Interface Configuration Manual page 98

Service aggregation router
Hide thumbs Also See for 7705:
Table of Contents

Advertisement

Card, Adapter Card, and Port Command Reference
report-alarm
Syntax
[no] report-alarm [loc] [lais] [lrdi] [lb2er-sd] [lb2er-sf] [slof] [slos] [lrei]
Context
config>port>sonet-sdh
Description
This command enables logging of SONET/SDH line and section alarms for a SONET/SDH port.
The no form of this command disables logging of the specified alarms.
Parameters
loc — reports a loss of clock that causes the operational state of the port to be shut down
lais — reports line alarm indication signal errors. When configured, line alarm indication signal
lrdi — reports line remote defect indication errors. Line remote defect indication errors are caused by
lb2er-sd — reports line signal degradation BER (bit interleaved parity) errors. When configured, line
lb2er-sf — reports line signal failure BER errors. When configured, line signal failure BER alarms
slof — reports section loss of frame errors. When configured, section loss of frame alarms are raised
slos — reports a section loss of signal error on the transmit side. When configured, section loss of
lrei — reports a line error condition raised by the remote end as a result of b1 errors received from
Page 98
Default
loss of clock alarms are issued
alarms are raised and cleared.
Default
line alarm indication signal alarms are not issued
remote loss of frame (LOF), loss of clock (LOC), and loss of signal (LOS) conditions. When
configured, line remote defect indication alarms are raised and cleared.
Default
line remote defect indication alarms are issued
signal degradation BER alarms are raised and cleared.
Default
line signal degradation BER alarms are not issued
are raised and cleared.
Default
line signal failure BER alarms are issued
and cleared.
Default
section loss of frame alarms are issued
signal alarms are raised and cleared.
Default
section loss of signal alarms are issued
this node. When configured, line error traps are raised but not cleared.
Default
line error traps are not issued
7705 SAR OS Interface Configuration Guide