7705 SAR OS Interface Configuration Guide
5. The test pattern procedure must be shut down before a new test-link value or test
pattern is accepted.
6. The current IMA group test pattern configuration and result of a given IMA test can
be seen by executing a show command for the IMA group. A test-link result can
have three values:
Disabled: the test-link is currently not running
Operating: the test pattern procedure is no shutdown and there are currently
no failed links for this running test-pattern procedure
Link-Failed: one or more links have failed the test-pattern procedure. Execute a
show port <slot/mda/port> ima-link command to see the failed
link and received pattern value.
7. Deleting a member link that is the same as the specified test-link, to stay in
compliance with key point 4, will result in the test-link value being reset to default.
8. IMA test procedure configurations are not saved when the admin save command is
executed.