Alcatel-Lucent 7705 Interface Configuration Manual page 161

Service aggregation router
Hide thumbs Also See for 7705:
Table of Contents

Advertisement

7705 SAR OS Interface Configuration Guide
Table 16: Show Port Detail Output Fields (SONET/SDH Port) (Continued)
Label
J0 String
Section Trace
Mode
Rx S1 Byte
Rx K1/K2 Byte
Rx J0 String
(Hex)
Cfg Alarm
Alarm Status
BER SD Threshold
BER SF Threshold
Hold time up
Hold time down
Sonet Section
ES-S
SES-S
SEFS-S
CV-S
LOS
LOC
LOF
OOF
B1 Error
Description
The section trace value that is sent to the far-end port
byte — the section trace in the SONET section header is set in bytes
string — a text string is used to identify the SONET section header
increment-z0 — an incremental STM ID is configured instead of
a static value
The value of the received SONET/SDH S1 byte
The value of the received SONET/SDH K1/K2 byte
The hex value of the received J0
The type of alarms to be logged and reported for the SONET/SDH port
The current alarm state
The configured threshold for line signal degradation BER error rate,
that when crossed determines the signal degradation and signal failure
The configured threshold for line signal failure BER error rate, that
when crossed determines the signal degradation and signal failure
The hold-timer value for link-up event dampening
The hold-timer value for link-down event dampening
SONET section statistics
The number of Errored Seconds errors
The number of Severely Errored Seconds errors
The number of Severely Errored Framing Seconds errors
The number of Code Violations errors
The number of Loss of Signal errors
The number of Loss of Clock errors
The number of Loss of Frame errors
The number of Out of Frame errors
The number of B1 errors
7705 SAR Interfaces
Page 161

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents