Figure 36 Removing the Front Airflow Guide
Replacing the Processor Airflow Guide
1.
Replace the front portion of the airflow guide:
a.
Align the release latch of the front half of the airflow guide over the release
latch post and snap it in place.
b.
Connect power connector on the front portion of the guide to the connector
on the system board.
c.
Replace server fans 1A and 1B.
2.
Replace the main portion of the airflow guide:
a.
Hold the opening on top of the processor airflow guide.
b.
At the same time, grasp the back end of the airflow guide and insert the
airflow guide into the server.
c.
Connect the power module cable and place the power and IDE cables in the
cable clips.
d.
Insert the two airflow guide retaining tabs into the two slots on the front half
of the airflow guide.
3.
Replace the top metal cover. Reconnect cables.
Removing and Replacing Memory DIMMs
Your server has 12 memory sockets for installing DDR SDRAM memory DIMMs. The
supported DIMM sizes are 256 MB, 512 MB, 1 GB, 2 GB, or 4 GB. The server supports
46