Replacing The Airflow Guide; Processor Power Connectors - HP Integrity rx2660 User's & Service Manual

Hide thumbs Also See for Integrity rx2660:
Table of Contents

Advertisement

Figure 3-13 Processor Power Connectors
Processor power
1
cable and connector
13. Close the processor cage.
a.
Grasp the processor cage handle and rotate the cage closure inward toward the rear of
the assembly until it is completely closed.
b.
Apply adequate force to push the handle down until it is flush with the cage.
14. Replace the airflow guide if you are finished installing additional components. See
the Airflow Guide" (page
15. Replace the top cover if you are finished installing additional components. See
the Top Cover" (page 63)

Replacing the Airflow Guide

Use this procedure to replace the airflow guide in the server when you are finished installing
additional equipment into the server.
To replace the airflow guide, follow these steps:
1.
Ensure the fan carrier handle is raised approximately 5 cm (2 in) to allow clearance for the
airflow guide replacement.
2.
Place the airflow guide on the edge of the fan carrier and set it down into place on the
processor cage (1).
3.
Push the fan carrier handle down until it is flush against the airflow guide (2).
System board power
2
cable and connector
57).
Figure 3-14 (page 58)
Processor
3
shows the fan carrier handle raised.
Installing Additional Components
"Replacing
"Replacing
57