Table 33 System Board Faults (continued)
System
LED 1
LED 2
LED
Flashing
GREEN
OFF
Red
Table 34 Fan Faults
System
LED 1
LED 2
LED
Flashing
GREEN
OFF
red
Flashing
OFF
GREEN
red
Flashing
OFF
OFF
red
Flashing
GREEN
GREEN
red
Flashing
OFF
GREEN
red
Flashing
GREEN
GREEN
red
Table 35 Processor Faults
System
LED 1
LED 2
LED
Flashing
RED
RED
Red
Flashing
RED
RED
Red
Flashing
RED
RED
Red
Table 36 BMC Faults
System
LED 1
LED 2
LED
Flashing
RED
GREEN
Red
Flashing
RED
GREEN
Red
LED 3
LED 4
Problem
RED
OFF
VRM
undervoltage
LED 3
LED 4
Problem
OFF
RED
Fan 1A fault
OFF
RED
Fan 1B fault
GREEN
RED
CPU 0-Fan
fault
OFF
RED
CPU 1-Fan
fault
GREEN
RED
Fan 2
(memory)
fault (both
rotors)
GREEN
RED
Fan 3
(disks/PCI)
fault (both
rotors)
LED 3
LED 4
Problem
GREEN
OFF
Processor 0
temperature
exceeds limit
OFF
GREEN
Processor 1
temperature
exceeds limit
GREEN
GREEN
No processor
detected
LED 3
LED 4
Problem
RED
OFF
BMC
firmware is
damaged
RED
GREEN
System board
FRU
Solution
Packard Enterprise Support
Engineer.
View the SEL for additional
information. For further
assistance, contact your Hewlett
Packard Enterprise Support
Engineer.
Solution
Replace the fan that is not
functioning.
Replace the fan that is not
functioning.
Replace the fan that is not
functioning.
Replace the fan that is not
functioning.
Replace the fan that is not
functioning.
Replace the fan that is not
functioning.
Solution
Make sure nothing is blocking the
server's airflow and locate your
server in an air-conditioned room.
In a single CPU configuration,
verify that the airflow blocker is
installed.
Verify that the processor or
processors are correctly installed.
Solution
Turn off and unplug the server.
Wait 20 seconds, then plug in and
restart the server. If the error
repeats, replace the base unit.
View the SEL for additional
information.
96