Wiring diagram or schematic

A wiring or a schematic diagram, and the ability
to read it are very important in troubleshooting a
circuit. The diagram shows how the circuit was
designed and what paths the electricity is sup-
pose to flow.

Fused jumper wires

Fused jumper wires are handy to help find bad
grounds or to jump across switches for testing
purposes.
CAUTION: Only use fused jumper wires. If there
is a short in the circuit, using an unfused jump
could damage components in the circuit.

Test lights

Test lights are used as a quick way to verify volt-
age at a point in a circuit. Like DVOMs, they
come in a wide variety from many manufactur-
ers.
The most basic test lights simply use the current
being checked to light an incandescent lamp.
These should not be used on any equipment
that has or may have solid-state circuitry.
The power necessary to light the bulb is more
than many solid-state circuits were designed to
handle. Components will be destroyed in the
process of testing them. See Figure 9.51.
Hi impedance test light:
Figure 9.51
If a test light is used at all, it should have "high-
impedance", indicating that it only takes a sam-
ple of the electricity being tested, and illuminates
an LED to indicate the presence of power.
Incandescent
GOOD
test light:
CAUTION
Some high impedance test lights are capable of
indicating whether the current being sampled is
AC or DC.
Self-powered continuity lights
Continuity lights can indicate whether a circuit is
complete or not, but they give no indication of
resistance. They are handy for finding point-
break when static-timing some older engines,
but have largely been replaced by DVOMs.
There are some powered high-impedance test
lights on the market that have a continuity fea-
ture, and some technicians like the fact that they
can be less bulky than a DVOM.

Battery Jumper Cables

The obvious use: jumper cables can be used to
jump-start equipment to get it into the shop. This
is not recommended for any fuel injected Kohler-
powered equipment.
The clever use: If the technician suspects that
there is resistance on the ground side of the sys-
tem, a quick-and-dirty test can be made using
jumper cables. See Figure 9.52.
Inset:
Block connection
Connect one cable clamp to the negative post of
the battery, and connect the clamp at the other
end of the same cable to the engine block.
If there is an immediate difference in starter
motor performance, use the voltage drop tech-
nique discussed later in this section to identify
the source of the resistance.
299
Chapter 9 - Electrical
Inset:
Battery connection
Figure 9.52