Vrt16-Da And Vrt16-D4 Monitor Operating Conditions; Vrt16-Da And Vrt16-D4 Monitor Nonoperating Conditions - DEC DECstation 5000 Model 100 Series Hardware Operator's Manual

Hide thumbs Also See for DECstation 5000 Model 100 Series:
Table of Contents

Advertisement

Table A-19 (Cont.). VRT16-DA and VRT16-D4 Monitor Description
– Sync pulse
Vertical rate timing
– Active video
– Blanking interval
– Frequency
– Front porch
– Sync pulse
– Vertical period
Video rate
– Pixel frequency
– Pixel period
Power
– ac input voltage
– Frequency
– Power consumption
Table A-20. VRT16-DA and VRT16-D4 Monitor Operating Conditions
1
Temperature range
Relative humidity
Maximum wet-bulb temperature
Minimum dew-point temperature
Altitude
1
Reduce maximum temperature by 1.8°C for each 1,000 meter (1.0°F for each 1,000 ft) increase in
altitude.
Table A-21. VRT16-DA and VRT16-D4 Monitor Nonoperating Conditions
Temperature range
Relative humidity
Maximum wet-bulb temperature
Altitude
1,335.1 ns
14.4915 ms
39 horizontal lines
66.4743 Hz
3 horizontal lines
3 horizontal lines
15.0434 ms
119.843 MHz
8.3443 ns nominal
90–132 or 198–264 Vac
Switch selectable
47 to 63 Hz
200 watts maximum
10°C to 40°C (50° to 104°F)
10% to 95%
32°C ( 89°F)
2°C (36°F)
10,000 ft maximum
40°C to 60°C (
40°F to 145°F)
10% to 95%
46°C (115°F) packaged
12,780 m (50,000 ft) maximum
Equipment Specifications A–17