Toshiba M500D User Manual page 70

Hide thumbs Also See for M500D:
Table of Contents

Advertisement

52
Connecting Components
Adding a SCSI hard disk drive
Device configuration (Configure/View Host Adapter
Setting)
To change the settings of a SCSI device or SCSI controller, first
select the SCSI controller, then select "Configure/View Host
Adapter Setting."
The table below lists the configuration parameters with their
default values and descriptions.
Item
Host Adapter
SCSI ID
SCSI Parity
Checking
Host Adapter
Boot Device
Options
Parameter/Setting
7
Enabled
SCSI Termination:
Enabled
Boot CSCSI ID: 0
Boot LUN Number: 0
Description
Selects the SCSI host
adapter's SCSI ID.
Don't change this setting
When enabled, the host
adapter uses SCSI parity
checking to verify the
accuracy of data transfer on
the SCSI bus.
Sets the SCSI bus termination.
Don't change this setting
Selects the device which starts
up the system. When you
select this item, the following
options appear:
Selects the SCSI ID of the
device which starts the system.
Don't change this setting.
Selects the LUN of the device
which starts the system.
Don't change this setting.

Advertisement