Running Manual Calibrate - IBM Infoprint 6700 Series User Manual

Hide thumbs Also See for Infoprint 6700 Series:
Table of Contents

Advertisement

255
191
Paper Out(144)
127
Gap Mark(105)
063
000
Figure 1. Media Profile Printout

Running Manual Calibrate

Manual Calibrate should be performed only when the values derived from
Auto Calibrate fail to improve the media sensors' ability to sense label length
indicators on the installed media. You must first enable "Admin User" in the
PRINTER CONTROL menu before accessing or initializing Manual Calibrate
in the CALIBRATE CTRL menu.
NOTE: Verify the Gap/Mark Sensor option (Gap, Mark, Advanced Gap,
Advanced Notch, or Disable) matches the installed media. See
"Sensing Different Media Types" on page 77.
Ensure the media sensors are horizontally positioned to permit
sensing of the label length indicators. See "Positioning The Media
Sensors" on page 72.
Ensure the Print Mode option selected in the QUICK SETUP menu
matches the media installed. Select "Direct" for heat sensitive media
(no ribbon required) or "Transfer" for thermal transfer media (ribbon
required).
If you try to do a Manual Calibrate when Peel-Off Media Handling is
enabled, the LCD will display, "CANNOT CALIBRATE/Disable Peel-
Off." Before you can do a Manual Calibrate, you must select another
media handling mode.
. .
1. Press
to place the printer in Menu mode.
.
2. Press the ↓ and
displays.
. .
3. Press
until "PRINTER CONTROL" displays.
.
4. Press ↑ until "Admin User" displays, then press
5. Press
to select Enable. An asterisk (*) appears next to "Enable."
keys together until "ENTER SWITCH UNLOCKED"
Running Manual Calibrate
+
until "Enable" displays.
81