DIAGNOSTICS
Software Build
This is the reference number which includes the program file part number and
revision number of the software installed in the printer, e.g., 358186 V1.07G.
Feature File
Displays the part number only when a feature file has been installed.
Hex Dump Mode
Disable (the default).
Enable. The printer prints out data sent from the host in hexadecimal
format.
Also see page 222.
Print Error Log
Prints the current log of errors. Most non-routine faults (RIBBON FAULT,
PRINT HEAD HOT) are stored in the error log.
Clear Error Log
Clears entries in the error log.
FLASH Installed
Displays the amount of FLASH memory installed in megabytes.
DRAM Installed
Displays the amount of DRAM installed in megabytes.
Ptr On Time
Displays the cumulative time in hours the printer has been powered on. This
value is set to zero at the factory after burn-in testing.
Ptr Media Dist
Displays the cumulative number of inches the printer has moved media. This
value is set to zero at the factory after burn-in testing.
Head Print Dist
Displays the length of media actually printed since the last Reset Head Data
operation. This value is set to zero at the factory after burn-in testing.