Manuals and User Guides for Nuvation Energy NUV100-CI-12-1. We have
2
Nuvation Energy NUV100-CI-12-1 manuals available for free PDF download: Product Manual
Nuvation Energy NUV100-CI-12-1 Product Manual (191 pages)
Low-Voltage BMS
Brand:
Nuvation Energy
| Category:
Control Systems
| Size: 14.18 MB
Table of Contents
Table of Contents
2
1 Introduction
8
About this Manual
8
2 Battery Topology Terminology
9
3 System Overview
10
Low-Voltage BMS
12
Cell Interface
13
Features
14
4 Installation Instructions
15
Low-Voltage BMS Mechanical Installation
15
Dimensions and Weight
15
Installation Location and Position
15
Mounting Instructions
16
Low-Voltage BMS Electrical Connections
17
Getting Started
17
Review Safety Considerations
18
Grounding and Fusing
19
Connect Communication Cables
22
Control / GPIO (Connector J5)
25
Battery Cells and Temperature (Connector J8)
29
Contactors / -V Power (Connector J6)
37
Current Shunt / +V Power (Connector J7)
40
Cell Interface Mechanical Installation
42
Dimensions and Weight
42
Installation Location and Position
43
Mounting Instructions
44
Cell Interface Electrical Connections
45
Getting Started
45
Connect Temperature Cable
46
Connect Battery Cells Cable
47
Connect the Link Bus Cable
52
First-Time Power-Up
53
Status Leds
54
5 Setting up the Operator Interface
55
Install the Operator Interface
55
Connect to the Operator Interface
56
Upgrading the Nuvation Energy BMS
59
Upgrading the Firmware
59
Upgrade Troubleshooting
60
Generate a Configuration File
61
Fine-Tuning the Configuration File (Optional)
61
Import the Configuration File
63
Configuration File Import Troubleshooting
64
Calibrate Your Nuvation Energy BMS
65
6 Using the Operator Interface
66
The Dashboard Tab
66
Warnings and Faults
66
Stack Voltage
67
Stack Current
67
State-Of-Charge
67
Depth-Of-Discharge
68
Cell Voltage
68
Temperature
69
Nuvation Energy BMS Status
70
The Details Tab
73
Addressing
73
Battery
73
Current Limiter
74
Safety
74
Cell Voltages
75
Thermistor Temperatures
76
Open Wire
77
The Menu Options
79
Registers
79
Service
79
Connection
80
Locking and Unlocking
81
About
82
The Status Banner
83
Service Lockout Indication
83
Communication Loss
83
Understanding the Service Lockout
84
Entering Service Lockout
84
Exiting Service Lockout
84
Shutdown Timer for Low-Voltage BMS
85
Service Lockout Troubleshooting
85
7 Configuration Settings
87
Background and Terminology
87
Register Data Model
87
Units
91
Storage Types
92
Configuration File
92
Factory Lockdown
93
Configuring Factory Registers
93
Enabling Factory Lockdown
93
Clearing Factory Lockdown
94
Restricted Register Write Operations
94
Address Resolution Restrictions
96
Battery Parameters
96
Stack Capacity
96
Stack Cycle Count
96
Current Full Threshold
98
Open Circuit Voltage Curve
98
Cell Resistance Estimation
98
Stack Topology
98
Cell Inputs
98
Thermistor Inputs
99
Operational Limits
99
Triggers
101
Cell Voltage Thresholds
102
Thermistor Temperature Thresholds
104
Stack Current Thresholds
106
Stack Voltage Thresholds
108
External Controller Heartbeat
110
Control Settings
110
Stack Switch Functions
111
Stack Current Limits
114
Passive Cell Balancing
115
Input / Output Assignment
117
Contactor Outputs
118
General Purpose Digital Outputs
119
General Purpose Digital Inputs
120
Protocol Settings
121
CAN Bus
121
RS485 Modbus RTU
128
Measurement Calibration
128
Thermistor Calibration
128
Stack Current Calibration
130
Stack Voltage Calibration
132
Hardware Settings
133
Link Bus Scan Period
134
Cell Voltage Low-Pass Filter
135
Cell Open Wire Detection and Diagnostics
135
Fault Pilot Signal
136
Under-Voltage Shutdown
137
Clock Verification
137
Open Shunt Detection and Diagnostics
138
Short Shunt Detection and Diagnostics
139
Temperature Consistency Check
140
Watchdogs and Freshness
142
Freshness
142
8 Communication Protocols
144
Modbus Protocol Support
144
Modbus RTU
144
Modbus TCP
144
Implemented MESA Models
144
MESA Model Structure and Nomenclature
145
Operational Cases for MESA
147
Accessing MESA Models
149
CAN Bus Protocol Support
151
CAN Reporting and Commands
151
Data Format
152
Data Size
152
9 External Interfaces
153
Low-Voltage BMS
153
Link out (Connector J1)
153
Ethernet / Modbus TCP (Connector J2)
154
CAN (Connector J3)
154
RS485 / Modbus RTU (Connector J4)
154
Control / GPIO (Connector J5)
155
Contactors / -V Power (Connector J6)
156
Current Shunt / +V Power (Connector J7)
157
Battery Cells and Temperature Sensors (Connector J8)
158
Cell Interface
161
Battery Cells
161
Temperature Sensors
163
Link in
164
Link out
165
10 Troubleshooting
167
Faults and Initialization Issues
167
Cell Voltage Faults
167
Stack Voltage Faults
168
Thermal Faults
168
Stack Current Faults
169
Pre-Charge Faults
170
Contactor Faults
170
Diagnostics Faults
171
Breaker Faults
172
Watchdog Faults
172
Miscellaneous Faults
174
Lost/Forgotten IP Address
175
Wireshark (Windows/Linux)
175
Netdiscover (Linux Only)
175
Appendix A: Operating Limits
177
Low-Voltage BMS
177
Electrical Characteristics
177
Environmental Conditions
179
Standards and Certifications
179
Cell Interface
180
Electrical Characteristics
180
Environmental Conditions
180
Standards and Certifications
181
Appendix B: Ordering Information
182
Low-Voltage BMS
182
Cell Interface
182
Appendix C: Changing the Nuvation Energy BMS Network Configuration
183
Modifying the Network Settings
183
Appendix D: Factory Reset
185
Appendix E: Best Practices
186
Excess Cable Management
186
Registers
188
Advertisement
Nuvation Energy NUV100-CI-12-1 Product Manual (109 pages)
High-Voltage BMS
Brand:
Nuvation Energy
| Category:
Control Systems
| Size: 11.5 MB
Table of Contents
Table of Contents
2
1 Introduction
6
About this Manual
6
2 Battery Topology Terminology
7
3 System Overview
8
Stack Switchgear
11
Features
12
Stack Controller and Power Interface
12
Current Measuring Shunt
12
DC Contactors
12
Pre-Charge Circuit
13
Fuses
13
Safety Relay (for E-Stop)
13
Cell Interface
14
4 Installation Instructions
15
Stack Switchgear Mechanical Installation
15
Dimensions and Weight
15
Installation Location and Position
16
Mounting Instructions
16
Stack Switchgear Electrical Connections
19
Getting Started
19
Ensure System Is De-Energized
20
Grounding the Stack Switchgear
21
Connect Power in
22
Connect Fan Control
23
Connect E-Stop
24
Connect Ethernet
26
Connect Link Bus
27
Connect Battery Stack and DC Bus
27
Cell Interface Mechanical Installation
29
Dimensions and Weight
29
Installation Location and Position
30
Mounting Instructions
31
Cell Interface Electrical Connections
32
Getting Started
32
Connect Temperature Cable
33
Connect Battery Cells Cable
34
Connect the Link Bus Cable
40
First Power-Up
41
Status Leds
42
5 Setting up the Operator Interface
44
Install the Operator Interface
44
Connect to the Operator Interface
45
6 Using the Operator Interface
48
The Dashboard Tab
48
Warnings and Faults
48
Stack Voltage
49
Stack Current
49
State-Of-Charge
49
Depth-Of-Discharge
50
Cell Voltage
50
Temperature
51
Nuvation Energy BMS Status
52
The Details Tab
55
Addressing
55
Battery
55
Current Limiter
56
Safety
56
Cell Voltages
57
Thermistor Temperatures
58
Open Wire
59
The Menu Options
61
Registers
61
Service
61
Connection
62
Locking and Unlocking
63
About
64
The Status Banner
66
Service Lockout Indication
66
Communication Loss
66
7 Communication Protocols
67
Modbus Protocol Support
67
Modbus TCP
67
Implemented MESA Models
67
MESA Model Structure and Nomenclature
68
Operational Cases for MESA
69
Accessing MESA Models
72
8 External Interfaces
75
Stack Switchgear
75
Battery Stack and DC Bus
75
Ethernet
75
Link Bus
76
E-Stop
76
Fan Control
77
Power in
77
Cell Interface
79
Battery Cells
79
Temperature Sensors
82
Link in
83
Link out
84
9 Servicing
86
10 Troubleshooting
87
Faults and Initialization Issues
87
Cell Voltage Faults
87
Stack Voltage Faults
88
Thermal Faults
89
Stack Current Faults
89
Pre-Charge Faults
90
Contactor Faults
90
Diagnostics Faults
91
Breaker Faults
93
Watchdog Faults
93
Miscellaneous Faults
95
Lost/Forgotten IP Address
95
Wireshark (Windows/Linux)
96
Netdiscover (Linux Only)
96
Appendix A: Operating Limits
97
Stack Switchgear
97
External Specifications
97
Electrical Characteristics
97
Environmental Conditions
98
Standards and Certifications
98
Cell Interface
99
Electrical Characteristics
99
Environmental Conditions
100
Standards and Certifications
100
Maximum Stack Deployment
100
Appendix B: Ordering Information
102
Stack Switchgear
102
Cell Interface
102
Appendix C: Best Practices
104
Excess Cable Management
104
System Noise
104
DC Filtering
105
Link Bus Power
106
Registers
109
Advertisement
Related Products
Nuvation Energy NUV100-CI-16-1
Nuvation Energy NUV300-BC-12
Nuvation Energy NUV300-BC-16
Nuvation Energy NUVSSG-1250-100
Nuvation Energy NUVSSG-1250-200
Nuvation Energy NUVSSG-1250-300
Nuvation Energy NUVG5
Nuvation Energy BMS NUVBCP-12S
Nuvation Energy BMS NUVBCP-16S
Nuvation Energy NUVP-G5-CCT-24
Nuvation Energy Categories
Control Systems
Controller
Network Hardware
Test Equipment
Control Panel
More Nuvation Energy Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL