The configuration file format is plain ASCII text with the following syntax:
Any lines starting with a leading # are treated as comments.
Each non-comment line is treated as a register assignment statement.
A register assignment takes on the form register_expression = value where:
register_expression is one of the valid
value is either a numerical constant, quoted string, IP address, or a valid
Any standard text editor can be used to edit configuration files (e.g. Notepad++, etc.).
A configuration file cannot be used to configure the IP settings of a stack. Stack IP
configuration is detailed in the
When a battery management system has been configured for
there are a set of components that will have all their register protected from most
write operations. Attempting to perform a write operation via a register addressing
(for example using a
further details.

7.2. Factory Lockdown

Factory Lockdown is a mechanism for users to lock registers with Factory storage type as read-only.
This is typically used to protect safety related configurations for safety certification purposes.

7.2.1. Configuring Factory Registers

Factory registers can be configured in the same way normal configuration registers can be set. They
can be set through the Operator Interface Registers menu option
uploading a configuration file. Factory registers can only be configured when the system is not in
Factory Lockdown.

7.2.2. Enabling Factory Lockdown

Factory Lockdown can be enabled by writing to specific registers from the Operator Interface. The
user must follow the process below for the Nuvation Energy BMS to be considered factory-locked.
1. Ensure all factory registers are configured to their desired value
2. Write 1 to sc_factory_lockdown.requested_state
3. Write 1 to sc_factory_persist.save
4. Wait until sc_factory_persist.save is equal to 0
5. Verify sc_factory_lockdown.actual_state is equal to 1
6. Write 1 to pi_factory_lockdown.requested_state
Document ID: NE-PM-002
Nuvation Energy Low-Voltage BMS - Product Manual
Register Expressions
Appendix
C.
Digital
Inputs) will silently fail. Please refer to
87
previously defined.
Register
Factory Lockdown
Section 7.2.4
(Section
6.3.1) or applied by
Rev 1.2, 2021-03-03