Link In - Nuvation Energy NUV300-BC-12 Product Manual

Low-voltage bms
Table of Contents

Advertisement

Pin
Connection
12
TEMP4_R
13
TEMP5_R
14
TEMP6_R
15
TEMP7_R
16
TEMP8_R
For safety certified applications there must be at least 2—but no more than
7—thermistors installed per Cell Interface module in a specific pattern. The following
table lists the expected pattern of thermistor installation approved for safety
certification.
Total Thermistors
TEMP1_R
7
Installed
6
Installed
5
Installed
4
Not Installed
3
Not Installed
2
Not Installed
9.2.2.1. Thermal Consistency
For safety certified systems, there is an additional constraint on thermal consistency for all
temperature measurements for each Cell Interface. The constraint is described in detail in
7.10.9.

9.2.3. Link In

This interface is used, with a Link Bus cable, to connect a single Cell Interface module to the Low-
Voltage BMS. Connect this interface to the
The Low-Voltage BMS cannot power the Cell Interface module through the Link Bus.
Document ID: NE-PM-002
Description
External Temperature Probe Input 4
External Temperature Probe Input 5
External Temperature Probe Input 6
External Temperature Probe Input 7
External Temperature Probe Input 8
Table 55. Safety Certified Thermistor Installation
TEMP2_R
TEMP3_R
Installed
Installed
Installed
Installed
Installed
Not Installed
Installed
Installed
Installed
Installed
Installed
Installed
Link Out connector
Table 56. Link In: Molex Micro-Fit 3.0 Connector
Nuvation Energy Low-Voltage BMS - Product Manual
TEMP4_R
TEMP5_R
Installed
Installed
Installed
Not Installed
Installed
Not Installed
Installed
Installed
Not Installed
Installed
Not Installed
Not Installed
Not Installed
Not Installed
Not Installed
on the Low-Voltage BMS.
158
Connected to Device
10 kΩ NTC Thermistor
10 kΩ NTC Thermistor
10 kΩ NTC Thermistor
10 kΩ NTC Thermistor
10 kΩ NTC Thermistor
TEMP6_R
TEMP7_R
TEMP8_R
Installed
Installed
Not Installed
Installed
Installed
Not Installed
Installed
Installed
Not Installed
Not Installed
Not Installed
Not Installed
Not Installed
Not Installed
Not Installed
Rev 1.2, 2021-03-03