Typically set to 50

7.10.8. Short Shunt Detection and Diagnostics

Nuvation Energy BMS can detect shorts in the stack current and stack voltage sensing circuit by
tracking the correlation between the stack voltage and stack current.
stack_short_shunt_detector.enabled
Set to 1 to enable the short shunt detection algorithm
stack_short_shunt_detector.current_activity_threshold
If a short circuit exists, the measured current would fall below this threshold value
A typical value, reported in mA, can be calculated taking into account the fuse rating (I
the stack in amps
stack_short_shunt_detector.voltage_activity_threshold
If voltage activity is detected above this threshold value, the detector looks for correlation
between the stack voltage and stack current.
A typical value, reported in mV, can be calculated using the current_activity_threshold (mA)
determined above along with the stack resistance (R
If the value of the stack resistance is not known, it can be calculated using the cell resistance (R
Ω and the number of cells in the stack (N
stack_short_shunt_detector.current_time_constant
The time constant of the filter used to remove noise in the current signal
Typically set to 1000000
stack_short_shunt_detector.voltage_time_constant
The time constant of the filter used to remove noise in the voltage signal
Typically this is set to 1000000
stack_short_shunt_detector.activity_detection_time
The settling time of the filter used to detect gradual changes in stack voltage The value also
represents the time required to detect these changes.
Typically set to 1800000000