4.4.4. Connect the Link Bus Cable

The Link Bus cable is used to connect the Low-Voltage BMS to a Cell Interface module. As long as the
system doesn't exceed the maximum 60 V DC limit, additional Cell Interface modules may be
connected in a daisy chain (called the Link Bus chain) using Link Bus cables. The Link Bus provides a
data channel and a power source to the Cell Interface.
Connection Procedure
1. Connect one end of the cable to the 'Link Out' connector on the Low-Voltage BMS.
2. Connect the other end of the Link Bus cable to the 'Link In' connector on the Cell Interface.
3. The 'Link Out' on the Cell Interface is to be left un-connected.
Document ID: NE-PM-002
Figure 37. Link Bus cable (NUVW-D05A00-010)
Nuvation Energy Low-Voltage BMS - Product Manual
46
Rev 1.2, 2021-03-03