Engineer Reset; Resetting Customer And Installer Codes (First Stage Reset); Return To Factory Defaults (Second Stage Reset) - Scantronic 808 Installation And Programming Manual

Hide thumbs Also See for 808:
Table of Contents

Advertisement

4. Programming
4.
Use the up and down arrow keys to view faults present on the system.
Remedy the faults, then press Menu until the display returns to the time
and date.
If the display shows a "CFG ERR" (configuration error),
for example:
Then see "9. Fault Finding - Error Messages" for an explanation of the
fault and how to correct it.

Engineer Reset

If you wish to perform an Engineer Reset without removing the end station
lid, type-in 0 (zero) + Engineer Code, (default 7890) then press Enter.

Resetting Customer and Installer Codes (First stage reset)

If the installer and/or user codes have been lost, or you need to return the
end station to the factory default access codes, you can load the default
codes as follows:
1.
Disconnect mains and battery power to the system.
2.
Place a small screwdriver blade between the pins marked 'RST' on the
main PCB.
3.
Apply battery and then mains power to the end station.
4.
Remove screwdriver blade from RST pins after three seconds.
The system loads the factory default access codes. (1234 for User and
7890 for Installer.) All user attributes return to default values.
In addition, the system re-initialises communications with all keypads.
The remaining programming is unchanged.

Return to Factory Defaults (Second stage reset)

If you need to return the end station to factory defaults (no programming and
an empty log) then:
1.
Follow steps 1 to 4 in 'Resetting Customer and Installer Codes'.
2.
Reset any alarms by keying-in the default User code and pressing
Enter.
3.
Key-in 0 (zero) followed by the default Installer code and then press
Menu.
The display shows:
4.
Press 0.
The display shows:
34
496234
CFG ERR A IN LA
MENU NO OR LEVEL
0:INST PROG

Hide quick links:

Advertisement

Table of Contents
loading