Engineer Reset

Engineer Reset
If you wish to perform an Engineer Reset without removing the end station
lid, type-in 0 (zero) + Engineer Code, (default 7890) then press Enter.

Resetting User and Installer Codes

If the installer and/or user codes have been lost, or you need to return the
end station to the factory default access codes, you can load the default
codes as follows:
1.
Disconnect mains and battery power to the system.
2.
Place a small screwdriver blade between the pins marked 'RST' on the
PCB.
3.
Apply battery and then mains power to the end station.
4.
Remove screwdriver blade from RST pins after three seconds.
The system loads the factory default access codes. (For four digit
codes: 1234 for User and 7890 for Installer. For six digit codes: 123456
for User and 567890 for Installer.) All user attributes return to default
values.
In addition, the system:
Disallows remote set/unset.
Unlocks any lockout imposed by Downloader.
Clears any message that may have been sent by Downloader.
Re-initialises communications with all keypads.
The remaining programming is unchanged.

Return to Factory Defaults

If you need to return the end station to factory defaults (no programming and
an empty log) then:
1.
Follow steps 1 to 4 in "Resetting User and Installer Codes".
2.
Reset any alarms by keying-in the default User code and pressing
Enter.
3.
Key-in 0 (zero) followed by the default Installer code and then press
Menu.
The display shows:
4.
Press Enter.
The display shows:
Note: The system can be programmed so that it does not ask for the End Station Lid
to be removed. See Menu 67.
18 of 44
496339 Issue 4
0:INSTALLER
PROGRAMMING
REMOVE END
STATION LID
8136