9448+/9448ES
Engineer Walk Test
Allows the engineer to test all devices on the system.
1.
Enter programming mode.
2.
Key in "97 ENTER".
The panel gives a continuous tone.
3.
Open and close each detector contact in turn.
When a detector contact is open the panel gives an interrupted tone and
flashes the zone LED.
4.
Press OMIT to stop the walk test.
Note that the Engineer's walk test allows you to test all zones including PA
zones, zone tampers, and panel and bell tampers. The user's walk test does
not allow this.