Engineer Walk Test; User Commands - Scantronic 9448 Plus Installation And User Manual

Alarm control panel
Hide thumbs Also See for 9448 Plus:
Table of Contents

Advertisement

9448+/9448ES

Engineer Walk Test

Allows the engineer to test all devices on the system.
1.
Enter programming mode.
2.
Key in "97 ENTER".
The panel gives a continuous tone.
3.
Open and close each detector contact in turn.
When a detector contact is open the panel gives an interrupted tone and
flashes the zone LED.
4.
Press OMIT to stop the walk test.
Note that the Engineer's walk test allows you to test all zones including PA
zones, zone tampers, and panel and bell tampers. The user's walk test does
not allow this.
Set/Unset System
Part Set
Omit zone
Keypad PA
Test Bells
Walk Test
Change User code
Chime On/Off
Read Log

User Commands

User code
2 + ENTER + User code
Zone number + Omit (repeat for all zones to be
omitted) + User code
1 + 3
4 + ENTER + User code
5 + ENTER User code
Omit to end test
6 + current user code
Current user code again
New user code.
7 + ENTER + User code
8 + ENTER +User code
<< for earlier events
>> for later events
496328 Issue 2
Engineer Walk Test
11 of 12