Programming Reference; Factory Defaults; System Users; Installer Programming - Scantronic 808 Installation And Programming Manual

Hide thumbs Also See for 808:
Table of Contents

Advertisement

5. Programming Reference

Factory Defaults

When delivered from the factory, the 808 is preprogrammed with the follow-
ing default settings:

System Users

UO1:
Access Code 1234, System Full Use, Zone omit Not Permit-
ted, Log Access = Permitted, Change Zone names = Permit-
ted, Change Data and Time = Permitted, Reset = Permitted
User 02-08:
Not Used (Duress=Disabled)
User 00:
Access Code = 7890

Installer programming

Menu 10:
Account Name
Menu 11:
Edit Name = No Name
Menu 20:
Zone Type
Menu 21:
Zone circuit type = CC
Menu 30:
Program zones
Menu 31:
Zone Names = ZO1: Zone 01 (all other zones to Zone [nnn])
Menu 32:
Zone Types = All zones Not Used (NU)
Menu 40:
Program multiflex
Menu 41:
Level Allocation = Level A,B,C,D = None
Menu 42:
Level Exit Mode = All Levels = Timed and terminate (Exit
Time = 10 Seconds)
Menu 43:
Level Entry Time = All Levels 20 Seconds
Menu 44:
Level Flexi-Zones = Not Set Up = NU
Menu 45:
Level Alarm response = All Levels = Full Alarm
Menu 46:
Level Re-Arms response = All Levels = Never
Menu 47:
Keypad allocation = None
Menu 50:
Program outputs
Menu 51:
Output Types = Bell = Normally On, Strobe = Normally Off,
All other NO Function
Menu 52:
Internal sounder = Follows Bell
Menu 53:
Bell Delay = 0, Bell Time = 20 Minutes
Menu 60:
Program System Options
Menu 61:
Installer information = Code = 7890
Menu 62:
PA response = Audible
Menu 63:
Line Fault response = Audible
Menu 64:
Allow Zone omits = Disabled
Menu 65:
System reset = Customer
Menu 66:
Logging Printer = Disabled
46
496234

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents