Anticode ResetForces the user to contact a central station and report the
circumstances of the alarm. If the central station decides that
the call does not require engineer attention, they give a reset
code to the user to reset the system. If engineer attention is
required, the system will be reset by the engineer on-site.
Note: You must program systems selected for 'Anticode Reset' with the same unique
Central Station ID (CSID) as used by the central station decoder. Contact your
central station for the correct CSID.
RedCare
Operates in conjunction with a plug-on RedCare Transmitter.
When an alarm condition occurs and the normal sequence of
events has been followed, the end user calls the central
station and they follow a verification procedure. The central
station uses the RedCare network to send a 'Tellback' signal
to the end station. The user can now enter a valid access
code to reset the system.
To select one these options, program the system reset as follows:
Customer Reset ENGRST D (Installer Reset Disabled)
Installer Reset
Anticode Reset
RedCare Reset ENGRST E, ATCODE D, REDCAREE (Installer Reset

66-PRINT OPTIONS

This menu allows you to enable or disable a logging printer connected to the
printer port.
Note: Use the C and D keys to enable or disable the logging printer.

67-MISC OPTIONS

This menu lets you change various miscellaneous options.
ALM ABT
Users may cause false alarms by remaining in a building
after the system has been set, or accidentally wandering into
a protected area. If communications are fitted the system will
transmit an unnecessary intruder signal to the central station.
To avoid false alarms from these causes the system has an
"Alarm Abort" time window of 180 seconds. This works as
follows:
ENGRST E, ATCODE D, REDCARED (Installer Reset
Enabled/Anticode Reset Disabled/RedCare Disabled)
ENGRST E, ATCODE E, REDCARED (Installer Reset
Enabled/Anticode Reset Enabled/RedCare/Disabled)
Enabled/Anticode Reset Disabled/RedCare Enabled)
496234
5. Programming Reference
57